TM 9–1200–215–34&P
2–38
2–21.
SERIAL I/O PORT CABLE, VGA CABLE, SCSI RIBBON CABLE MAINTENANCE
INSTRUCTIONS CONTINUED
a.
REMOVAL CONTINUED
10. Remove connector cap (31).
NOTE
The female screwlocks are an
assembly.
They can be reused.
11.
Remove two female screwlocks (32) securing
Serial I/O, VGA, or SCSI ribbon cable
connector (33, 34, or 35) respectively, to ACU.
12. From the interior of the ACU, remove ribbon
cable (10, 11, or 16).
13. Inspect connector gasket (36, 37, or 38) for
cuts, nicks, or signs of stretching.
Discard
gasket if unserviceable.
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
If removed, install connector gasket (36, 37, or
38) on ribbon cable connector (33, 34, or 35),
respectively.
3.
Position ribbon cable connector (33, 34, or 35)
in ACU.
WARNING
•
Do not breathe fumes from
adhesive/sealant.
Use with
adequate ventilation.
•
Adhesive/sealant may cause eye or
skin irritation; avoid direct contact.
4.
Apply surface primer and sealing compound to
two female screwlocks (32) per connector.
5.
Secure ribbon cable connector (33, 34, or 35)
by inserting two female screwlocks (32).
Change 1