TM 9–1200–215–34&P
2–34
2–20.
LED
MAINTENANCE INSTRUCTIONS CONTINUED
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The ACU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
NOTE
Insulation sleeving tubing should be
twice the diameter of the part over
which it will be shrunk.
2.
Slide a 1 in. piece of insulation sleeving (11)
onto end of each lead (6).
3.
Position LED body (7) with gasket (10) into
ACU housing (5) and install star washer (9)
and nut (8).
4.
Solder leads to back of LED.
Remove tags.
5.
Clean solder joints with acid swabbing brush
and alcohol.
6.
Slide insulation sleeving into position.
7.
Using heat gun, apply heat until sleeving forms
to shape of wire and terminal.
8.
Tighten nut (8) and star washer (9).
11
8
9
5
10
7
5
11
6
6