TM 9-2320-328-13&P-2
0116-11
DRAFT
0116
Change 1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3182
.
Step 22.
Install circuit breaker FS 19 (WP 0242).
Remove relay 1 (WP 0244).
Remove one rear
lower center clearance light (WP 0229).
With a test lead set, check for continuity across
wire 1606 (green) from cab power distribution block relay 1 connector, terminal 5 to rear
lower center clearance light connector terminal.
.
If there is no continuity, go to Step 27.
.
Step 23.
With a test lead set, check for continuity across cab power distribution wire harness wire
1640 (black) from relay 1 connector, terminal 2 to a known good ground.
.
If there is no continuity, replace cab power distribution wire harness and
block (WP 0280).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION