TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 113 of 1616

TM 9-2320-440-13&P
0016-11
0016
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
When both MRP locks are fully disengaged, the RACK LOCKS ENGAGED indicator light
will be extinguished.
1.
Verify that both MRP rack locks are disengaged (WP 0012).
2.
Ensure MRP deck-to-subframe locks are engaged (Refer to THAAD Launcher IETM).
3.
Disconnect umbilical and ADU/IL cables (Refer to THAAD Launcher IETM).
4.
Disconnect MRP from vehicle ground (WP 0010).
5.
Connect vehicle to ground rod with static reel clamp.
6.
Connect MRP to ground rod with static reel clamp (refer to THAAD Launcher IETM).
7.
Disconnect the vehicle ground cable and stow near passenger side tie down.
8.
Stow MRP under-run bumper (Refer to THAAD Launcher IETM).
9.
Check
for sufficient operating room at front and rear of vehicle.
Check overhead clearance and ground
conditions.
10.
Apply service brake pedal (1) and set transmission range selector (2) to N (Neutral).
THAAD0198
THAAD0275


Back to Top