  TM-9-2330-342-23-P - Page 332 of 1348

MULTIFUNCTION
VALVE
FRONT END
AIR LINE 2620
TRANSDUCER
Figure 3.
Multifunction Valve and Air Line 2620.
4.
Meter should display a reading of 125 ± 5 psi (861 ± 34 kPa).
CONDITION/INDICATION
Does parking brake valve supply 125 ± 5 psi (861 ± 34 kPa) through hose 2620?
DECISION
Yes - Go to (Step 4 - Does test equipment pass offset test?).
No - Replace parking brake valve (WP
0074). Go to (Step 6 - Does test equipment pass offset test?) to verify problem
is solved.
STEP 4
Does test equipment pass offset test?
WARNING
Be sure to wear the proper eye protection when working on or around pressurized air systems
if not injury or death could result.
1.
Pull out trailer charge valve in vehicle. Refer to vehicle Operator's manual (WP
0190)
2.
Have assistant turn engine start switch to OFF. Refer to vehicle Operator's manual (WP
0190).
3.
Disconnect TK pressure transducer (blue stripe) from air hose 2620.
4.
Connect air hose 2620 to multifunction valve.
5.
Disconnect air hose 2605 from air reservoir 2.
6.
Connect TK pressure transducer (blue stripe) to air hose 2605.
TM 9-2330-342-23&P
0031
0031-4


Back to Top