FIELD MAINTENANCE
TRAILER AIR SYSTEM WILL NOT CHARGE OR MAINTAIN A CHARGE
INITIAL SETUP:
Tools and Special Tools
MSD/ICE, Test Set, Electronic Systems
(WP
0194, Table 1, Item 27)
MSD-V2, Test Set, Electronic Systems
(WP
0194, Table 1, Item 28)
Tool Kit, General Mechanic’s: Automotive
(WP
0194, Table 1, Item 47)
Materials/Parts
Solution, Soap (WP
0193, Table 1, Item 58)
Personnel Required
Wheeled Vehicle Mechanic (2)
References
WP
0004
References (cont.)
WP
0067
WP
0068
WP
0069
WP
0070
WP
0073
WP
0074
WP
0076
WP
0081
WP
0084
WP
0086
Equipment Condition
Parking brake applied (TM 9-2330-342-10).
(WP
0190)
Wheels chocked (TM 9-2330-342-10). (WP
0190)
TROUBLESHOOTING PROCEDURE
TRAILER AIR SYSTEM WILL NOT CHARGE OR MAINTAIN A CHARGE
STEP 1
Are air lines, fittings, valves, and/or reservoirs free of leaks?
NOTE
•
Soap and water solution will be used to visually check for leaks.
•
125 ± 5 psi (861 ± 34 kPa) must be supplied to trailer air system before
troubleshooting can begin.
1.
Have assistant turn engine start switch to ON. Refer to vehicle Operator's manual (WP
0190).
2.
Push in trailer charge valve in vehicle. Refer to vehicle Operator's manual (WP
0190).
TM 9-2330-342-23&P
0031
0031-1