TRANSDUCER
AIR LINE
2605
NO. 2 AIR
RESERVOIR
Figure 4.
Air Reservoir and Air Line 2605.
7.
Connect TK pressure test cable to MSD/ICE test equipment (WP
0004) and to TK pressure transducer (blue
stripe).
8.
Perform ICE Offset Test 50.
CONDITION/INDICATION
Does test equipment pass offset test?
DECISION
Yes - Go to (Step 5 - Does multifunction valve supply 125 ± 5 psi (861 ± 34 kPa) through hose 2605?).
No - Test equipment failed offset. Contact your Supervisor.
STEP 5
Does multifunction valve supply 125 ± 5 psi (861 ± 34 kPa) through hose 2605?
1.
Have assistant turn engine start switch to ON. Refer to vehicle Operator's manual (WP
0190).
2.
Perform ICE Test 50.
3.
While assistant pushes in trailer charge valve in vehicle, observe meter reading. Refer to vehicle Operator's
manual (WP
0190).
TRANSDUCER
AIR LINE
2605
NO. 2 AIR
RESERVOIR
Figure 5.
Air Reservoir and Air Line 2605.
4.
Meter should display a reading of 125 ± 5 psi (861 ± 34 kPa).
TM 9-2330-342-23&P
0031
0031-5