TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 49 of 783

TM 9-2350-260-20-1-3
STARTER LOW VOLTAGE RELAY SOLENOID REPLACEMENT (2D ENGINE) (Sheet 2 of 2)
INSTALLATION:
NOTE
Be sure insulators (E) are placed
between relay solenoid (A) and
engine mounting bracket (B) as
shown.
1.
Place relay solenoid (A) in position over mounting
bracket (B) with electrical plug (C) facing front.
Using socket and 7/16 inch wrench, secure solenoid
(A) to mounting plate (B) with two capsrews (D),
insulators (E), and new self-locking nuts (F).
2.
Screw electrical connector (G) to front of relay
solenoid (A).
Tighten, using spanner wrench.
TEST:
1.
Connect powerplant for ground hop (page 5-54).
2.
Start engine (TM 9-2350-260-10).
Check to be sure
engine starts smoothly.
3.
Stop engine.
Disconnect powerplant from test
set-up (page 5-67).
4.
Install 2D powerplant (page 5-40).
End of Task
TA147069
10-37


Back to Top