TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 579 of 1008

TM 9-2350-261-20-2
REPLACE UTILITY OUTLET RECEPTACLE (ALL EXCEPT
M577A2 AND M1068)
0329 00
THIS WORK PACKAGE COVERS:
Removal (page 0329 00-1).
Inspection-Acceptance and Rejection Criteria (page 0329 00-2).
Installation (page 0329 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 42)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Locknut (8)
Lockwasher (2)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (WP 0294 00)
Warning light panel assembly removed (WP 0253 00)
REMOVAL
1.
Disconnect circuit 37 lead (1) from utility outlet receptacle lead (2).
2.
Slide shell connector (3) down lead (2). Remove slotted washer (4) from lead. Remove shell connector from lead.
3.
Remove eight locknuts (5), washers (6), screws (7), and master switch panel (8) from distribution box (9). Discard
locknuts.
032900-1


Back to Top