TM 9-2350-261-20-2
REPLACE REAR BILGE PUMP AND STRAINER — Continued
0325 00
8.
Install bracket (1) on weldnuts. Secure with two new key washers (2) and screws (3).
9.
On M1064, place strainer (4) on pump (5). Secure with washer (6) and screw (7).
10. Connect circuit 451 lead (8) to bilge pump (5).
FOLLOW-THROUGH STEPS
1.
Install smoke generator fog oil tank module (M1059 Only) (WP 0695 00).
2.
Connect battery ground lead (WP 0294 00).
3 .
Turn MASTER SWITCH to O N (see you r
-10).
4 .
Turn BILG E P UMP sw itch O N (see you r
-10) and check p um p.
5 .
Turn BILG E P UMP sw itch O FF (see you r
-10).
6.
Raise and lock ramp (see your -10).
7.
Stop/shutdown engine (see your -10).
8.
Install rear floor plates (WP 0436 00, WP 0437 00, WP 0438 00, WP 0440 00, or WP 0441 00).
END OF TASK
0325 00-5/6 blank