TM 9-2350-261-20-2
REPLACE REAR BILGE PUMP AND STRAINER — Continued
0325 00
INSTALLATION
1.
M1064 only, place bracket (2) on new pump (3). Secure with screw (4) and new locknut(5).
2.
Install adapter (6) in pump (3). Use adjustable wrench. Place ground lead (7) on pump. Secure with two new
lockwashers (8) and screw (9).
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
3.
Secure cushion (1) to pump (3) with adhesive.
4.
Install pump (3) in carrier. Slide hose (10) on adapter (6) and secure with clamp (11).
5.
Place strainer (12) (M1064 only) or strainer (13) (all other carriers) on hull weldnuts.
6.
Install bracket (14) on weldnuts.
7.
Secure with three new lockwashers (15), ground lead (7), new key washer (16), and two screws (17).
0325 00-4