TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 873 of 1047

TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM (MFCS) CABLES
(M577A3 ONLY) — Continued
0812 07
CAUTION
To prevent damage to equipment, ensure power is turned off at power distribution assembly
(PDA) before disconnection of cable.
NOTE
Steps 8 - 11 apply to cable 4W7, power/data cable for commander’s interface.
8.
Disconnect P6 connector of cable 4W7 (12) from J3 connector (14) on commander’s interface (CI) (13).
9.
Disconnect P2 connector of cable 4W7 (12) from J3 connector (15) on PDA (11).
10. Disconnect P8 and P9 connectors of cable 4W7 (12) from connection points on two SINCGARS radios (17) and (16).
11. Remove tie straps from cable 4W7 (12) and remove cable from vehicle.
0812 07-4
Change 4


Back to Top