TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
CAUTION
To prevent damage to equipment, ensure power is turned off at power distribution assembly
(PDA) before disconnection of cable.
NOTE
Steps 16 - 22 apply to cable 3W2, power/data cable for precision lightweight GPS receiver
(PLGR).
16. Disconnect P3 connector of cable 3W2 (27) from J1 connector of cable 3W1 (14) at cable bracket (17) on battery box.
17. Follow route of cable 3W2 (27) from battery box to cable bracket (28) on driver’s side sponson. Remove loop clamps
and tie straps as necessary to release cable.
18. Disconnect J4 connector of cable 3W2 (27) from P4 connector of cable 3W3 (29) at cable bracket (28) on driver’s
side sponson.
0812 14-6
Change 5