TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 916 of 1047

TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
NOTE
Steps 7 - 28 apply to cable 3W5, power/data cable for pointing device (PD) and gunner’s
display (GD).
7.
If installed, lift and secure two gunner’s side turntable access covers. Refer to TM 9-1015-232-23&P.
8.
If missing, install two turntable stops. Refer to TM 9-1015-232-23&P.
9.
If installed, remove bilge pump floor plate (WP 0543 00) and fuel valve panel (WP 0197 00).
WARNING
Metal chips and grinding dust can cause eye injury. Wear goggles and gloves.
NOTE
If cable 3W5 is being installed in vehicle for the first time, proceed with Step 10. Also notify
direct support maintenance for preparation of turntable wall. If cable is being installed in
previously-modified vehicle, go to Step 16.
10. Near rear of center beam of turntable, locate the “I” beam support pin. Measure 3.75 in. (9.5 cm) back and 2.0 in. (5.1
cm) from bottom of support beam. Mark location and drill a 0.159 in. (0.4 cm) through hole (56). Thread hole with
10-32 tap.
0812 14-15
Change 5