TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
CAUTION
To prevent damage to equipment, ensure power is turned off at power distribution assembly
(PDA) before disconnection of cable.
NOTE
Steps 36 - 38 apply to cable 34W7, power adapter cable for precision lightweight GPS receiver
(PLGR).
36. Disconnect cable 34W7 (33) from P1 connector of cable 3W2 (27).
37. Disconnect cable 34W7 (33) from J4 connector (32) on PLGR (31).
38. Remove cable from vehicle.
0812 14-11
Change 5