REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
CAUTION
To prevent damage to equipment, ensure power is turned off at power distribution assembly
(PDA) before disconnection of cable.
NOTE
Steps 23 - 36 apply to cable 3W3, power/data cable for pointing device (PD) and gunner’s
display (GD).
23. Disconnect P1 connector of cable 3W3 (29) from J1 connector (36) on pointing device (PD) (37).
24. Disconnect P2 connector of cable 3W3 (29) from J2 connector (38) on PD (37).
25. Disconnect P3 connector of cable 3W3 (29) from J1 connector (35) on gunner’s display (GD) (34).
26. Lift and secure two gunner’s side turntable access covers (39). Refer to TM 9-1015-232-23&P.
27. Remove bilge pump floor plate (40) (WP 0543 00) and fuel valve panel (41) (WP 0197 00).
0812 14-8