TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 902 of 1047

TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES
(MFCS) (M1064A3 ONLY)
0812 14
THIS WORK PACKAGE COVERS:
Removal (page 0812 14-1).
Repair (page 0812 14-13).
Installation (page 0812 14-14).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Electronic Equipment Tool Kit (WP 0926 00, Item 66)
Shop Set, Small Arms (WP 0926 00, Item 46.1)
Materials/Parts
Loop clamp (AR) (WP 0928 00, Item 14.5)
Loop clamp (AR) (WP 0928 00, Item 14.1)
Loop clamp (AR) (WP 0928 00, Item 14.2)
Loop clamp (AR) (WP 0928 00, Item 14.4)
Loop clamp (AR) (WP 0928 00, Item 14.3)
Tie strap (AR) (WP 0928 00, Item 61.2)
Tie strap (AR) (WP 0928 00, Item 61.1)
Materials/Parts
Tie strap (AR) (WP 0928 00, Item 61.3)
Lockwasher (2)
Self-locking nut (2)
Personnel Required
Mechanic
References
TM 9-1015-232-23&P
TM 9-1220-248-10
TM 11-5820-890-10-7
TM 9-1220-248-23&P
WP 0197 00
WP 0543 00
Equipment Condition
Master switch OFF (TM 9-2350-277-10)
REMOVAL
CAUTION
To prevent damage to equipment, ensure power is turned off at power distribution assembly
(PDA) before disconnection of battery cable.
NOTE
Refer to TM 9-1220-248-23&P for wiring diagram.
081214-1
Change 5