TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
19. Disconnect P1 connector of cable 34W7 (33) from J4 connector (32) on precision lightweight GPS receiver (PLGR) (31).
20. Disconnect P2 connector of cable 3W2 (27) from J2 connector (30) on PLGR (31).
21. Lift cable 3W2 (27) from position under troop seat and remove from vehicle.
22. Disconnect J4 connector of cable 34W7 (33) from P1 connector of cable 3W7 (27).
081214-7