REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
NOTE
Steps 29 - 35 apply to cable 3W2, power/data cable for precision lightweight GPS receiver
(PLGR).
29. Install J4 connector of cable 3W2 (27) to cable bracket (28) on driver’s side sponson.
30. Route P3 branch of cable 3W2 (27) along driver’s side wall of vehicle, beneath the vertical ammo racks and the troop
seat. Attach cable to existing hardware using loop clamps (65) (WP 0928 00, Item 14.4) with flat washers (64), socket
head capscrews (63), and tie straps as required.
0812 14-20
Change 5