TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
42. Route J1 connector of cable 3W1 (14) to right rear corner, behind fire extinguisher, and down side of battery box (66) to
cable bracket (17).
43. If removed, install cable bracket (17), two hexagon head capscrews (18), flat washers (16), and new self-locking nuts
(15) on battery box (66).
44. Install J1 connector (67) in cable bracket (17).
0812 14-24