TM 9-2350-277-20-5
REPAIR/REPLACE MORTAR FIRE CONTROL SYSTEM CABLES (MFCS)
(M1064A3 ONLY) — Continued
0812 14
23. Connect P3 connector of cable 3W3 (29) to J1 connector (35) on GD (34).
24. Connect P2 connector of cable3W3 (29) to J2 connector (38) on PD (37).
25. Connect P1 connector of cable 3W3 (29) to J12 connector (36) on PD (37).
26. Stow excess cable in turntable well. Secure with tie straps as necessary.
27. Lower two gunner’s side turntable access covers. Refer to TM 9-1015-232-23&P. Ensure that P3 branch of cable 3W3
(29) is positioned in notch in access cover and that P1/P2 branch of cable 3W3 is not pinched by access cover.
28. Install bilge pump floor plate (40) (WP 0197 00) and fuel valve panel (41) (WP 0543 00).
0812 14-19
Change 5