TM 9-2350-277-34
REPLACE INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) (OUTBACK ONLY) — Continued
0094 01
17. Reinstall plastic cover (49) with two screws (48) on inverter.
18. Remove the terminal covers (41) by inserting a flat blade screw driver into the slots on the sides of the positive and
negative terminal cover and snapping the terminal cover off the studs. Remove nut (45), lockwasher (44), flat washer
(43), and turbo fan lead (47) from positive stud (red) (39). Repeat procedure for negative stud (black) (37).
19. Install lug of cable (40), turbo fan lead (47), flat washer (43), and lockwasher (44) on positive stud (red) (39) and secure
with nut (45). Repeat procedure for negative stud (black) (37) using lug of cable (38).
20. Reinstall turbo fan cover (42) on inverter (31) using four screws (46).
0094 01-19
Change 5