TM 9–2350–311–20–2
9–1
CHAPTER 9
CAB ELECTRICAL CONTACT BOARD AND CONTACT ARM ASSEMBLIES
GENERAL
This chapter describes and illustrates maintenance procedures for contact board segments and electrical contact arm and
holder assembly. Maintenance functions assigned to unit level include replacement, repair, testing, cleaning, and adjust-
ment.
CONTENTS
Page
9–1
CONTACT BOARD SEGMENTS FOR 5 CONTACT ARM ASSEMBLIES
9–2
. . . . . . . . . . . . . . . . . . . . .
9–2
CONTACT BOARD SEGMENTS FOR 3 CONTACT ARM ASSEMBLIES
9–5
. . . . . . . . . . . . . . . . . . . . .
9–3
ELECTRICAL CONTACT ARM ASSEMBLY
9–8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE
•
Because some howitzers have 3 rather than 5 contact arm assemblies, some variations in
maintenance procedures are required. Howitzers with 3 contact arm assemblies have these
differences when compared to howitzers with 5 contact arm assemblies:
•
3 contact arm assembly howitzers have 2 ring segments instead of one.
•
3 contact arm assembly howitzers have covers for the ring segments.
•
Ring segments on 3 contact arm assembly howitzers have more fasteners than ring segments
on 5 contact arm assembly howitzers.