TM 9–2350–311–20–2
9–6
9–2
CONTACT BOARD SEGMENTS FOR 3 CONTACT ARM ASSEMBLIES — CONTINUED
a.
Removal
WARNING
While performing all procedures in this section except for testing, disconnect the battery ground ca-
ble at battery terminal to cut off cab electrical power. Failure to observe this warning could result in
severe burns and electrical shock, resulting in injury or death.
NOTE
This procedure is written for one contact arm assembly, but applies to all three.
1
Remove six cap screws (1), six flat washers (2), and six self-locking nuts (3). This will release ring segment
shield (4). Repeat procedure for other ring segment shield. Discard self-locking nuts.
2
Remove two machine bolts (5), two lockwashers (6) and two hex nuts (7). This will release power cable (8)
at bus bar terminal (9). Discard lockwashers.
NOTE
All harnesses must be tagged or marked to assure correct assembly.
3
Remove ten machine screws (10) securing harnesses (11 and 12). Lift off harnesses.
CAUTION
Use care in removing or installing ring segments. Place ring segments in a safe place to prevent
damage to the silver contact surface.
4
Remove eight self-locking screws (13) and eight flat washers (14). This will release ring segment (15). Re-
peat step for other ring segment. Discard self-locking screws.
5
6
7
2
3
1
10
4
13
15
14
SEGMENT RING AND COVER WITH