TM 9-2520-270-34
47. INSPECT WIRE FABRIC (1).
a.
b.
c.
Inspect fabric (1) for dirt. If fabric
is plugged, clean it. See page 2-2.
Inspect fabric (1) for loose or bent
wires.
If fabric (1) is damaged, housing (2)
must be replaced. Go to step 55. If
fabric is not damaged, go to step 48.
49. CHECK MECHANICAL HOUSING (4).
a. Using micrometer caliper set,
measure outside diameter of
mechanical housing (4).
b. If measurement is less than
4.3288 inches (109.952 mm), go
to step 55. If not, go to step 50.
48. CHECK OUTPUT BEARING
SUPPORT (3).
a. Using micrometer caliper set,
measure outside diameter of bearing
support (3).
b. If measurement is less than
3.3443 inches (84.945 mm), go to
step 55. if not, go to step 49.
50. CHECK MECHANICAL HOUSING (5).
a. Using micrometer caliper set,
measure two outside diameters (6)
and one outside diameter (7) on
mechanical housing (5).
b. If either measurement (6) is less
than 2.9990 inches (76.175 mm), go to
step 55. If not, go to step 50c.
c. If measurement (7) is less than
3.3445 inches (84.950 mm), go to
step 55. If not, go to step 51.
4-246