TM 9-2520-270-34
24. REMOVE PRESSURE FLUID
FILTER (1).
a. Using 3/8-inch drive ratchet handle and
5/16-inch socket wrench attachment,
remove filter (1).
b. Remove preformed packing (2).
25. INSPECT FILTER (1) AND
FILTER CAVITY (3).
a. If metal chips are found, go to
step 26. If not, discard packing (2)
and go to step 28.
28. CHECK ACTUATOR VALVE
ASSEMBLY (4).
a. Move valve assembly (4) in and out of
piston (5).
b. If valve assembly (4) binds, go to
step 29. If not, go to step 32.
26. INSTALL FILTER (1).
a. Install packing (2) on filter (1).
b. Install filter (1).
c. Tighten filter (1).
27. GO TO STEP 39.
29. REMOVE VALVE ASSEMBLY (4).
a. Carefully pull valve assembly (4)
straight out of hole in piston (5).
30. REPLACE VALVE ASSEMBLY (4).
31. GO TO STEP 34.
32. REMOVE VALVE ASSEMBLY (4).
a. Carefully pull valve assembly (4)
straight out of hole in piston (5).
GO TO NEXT PAGE
4-375