TM-9-2520-270-34

HYDROMECHANICAL CROSSDRIVE, TRANSMISSION HMPT 500 AND TRANSMISSlON CONTAINER ASSEMBLY

TECHNICAL MANUAL; DIRECT AND GENERAL SUPPORT MAINTENANCE

NOVEMBER 1984

  TM-9-2520-270-34 - Page 795 of 933

TM
9-2520-270-34
8.
TURN TRANSMISSION
CONTROLLER SIDE UP.
CAUTION
Use care when disconnecting linkage.
Attaching parts are small and can fall into
transmission during removal. Damage to
equipment can occur.
9. DISCONNECT CONNECTING LINK (1)
AND SHAFT REVERSE LINK (2).
a. Using 3/8-inch drive ratchet handle
and 3/8-inch socket, remove
self-locking nut (3). Discard nut.
b. Remove bolt (4) and sleeve bushing (5).
Separate links (1) and (2). Discard bolt.
10. REMOVE CROSS SHAFT
ASSEMBLY (6).
a. Remove cross shaft assembly (6) with
link (1) and place on work surface.
11. REMOVE LINK (1).
a.
b.
Using 3/8-inch drive ratchet handle
and 3/8-inch socket, remove and
discard self-locking nut (7).
Remove bolt (8), sleeve bushing (9),
and link (1). Discard bolt.
GO TO NEXT PAGE
4-459


Back to Top