TM 9-2520-272-40
0013
REMOVE G2 BACKUP VALVE ASSEMBLY
NOTE
Top cover assembly is removed from transmission.
Wiring harness does not have to be removed to remove G2 backup valve assembly.
Transmission is upright on foororworktab
le
.
1. Disconnect plastic connectors that attach wiring harness to solenoids.
2. Remove two 1/4-18 x 2-1/4 inch bolts (Figure 1, Item 1) and two washers (Figure 1, Item 2) that attach G2
backup valve assembly (Figure 1, item 5) to separator plate (Figure 1, Item 4).
3. Remove two 1/4-18 x 1-3/4 inch bolts (Figure 1, Item 3) and two washers (Figure 1, Item 2) that attach G2
backup valve assembly (Figure 1, item 5) to separator plate (Figure 1, Item 4).
4. Remove G2 backup valve assembly (Figure 1, Item 5).