Fig. 5-171
Fig. 5-177
Remove
1. Cut locking wire (A).
2. Remove 12 bolts (B) attaching accessory drive gear to
flange on crankshaft.
Install
1. Install 12 bolts (B) securing accessory drive gear to
flange on crankshaft.
2. Install locking wire (A) securing bolts.
1. Install three 7/16 x 1-1/8 in. accessory drive gear
mounting bolts (A) in tapped holes provided in ac-
cessory drive gear.
Z. Alternately tighten bolts (B) and pull accesory drive
gear from flange on crankshaft. Remove puller bolts
from gear.
Figure 5-170. Removing accessory drive gear
using mounting bolts as puller screws.
Figure 5-169. Removing or installing acces-
sory drive gear attaching parts.
5-15. Crankshaft and Connecting Rod
Refer to Table 5-12 for illustrations and
Assembly,
Piston
Oiler
Nozzles,
disassembly instructions. Figure references are
Generator and Starter Idler Gears, and
listed in the table.
Starter Driven Gearshaft
Table 5-12. Crankshaft and Connecting Rod Assembly, Piston
Oiler Nozzles, Generator
and
Starter Idler Gears,
and Starter Driven Shaft
Crankshaft and Connecting Rod Assembly and Piston Oiler
Nozzles
Generator and Starter Idler Gears and Starter Driven
Gearshaft
5-97