TM-9-2815-205-24

6V53/6V53T ENGINES, DIESEL WITH CONTAINERS; MODEL 5063-5299, MODEL 5063-5392, MODEL 5063-5393 AND MODEL 5063-539L

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE

FEBRUARY 2013

  TM-9-2815-205-24 - Page 564 of 856

CLEANING
1.
Injector spray tip cleaning procedures:
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes; and do not breathe vapors. Keep away from heat or flame. Never
smoke when using cleaning solvent. Failure to comply may result in injury,
illness, or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa).
Use only with protective equipment (goggles, face shield, gloves, etc.). Failure
to comply may result in injury to personnel.
a.
Soak spray tip in cleaning solvent to loosen carbon.
CAUTION
Do not contact needle valve seat with carbon remover during spray tip insertion or
valve seat could be damaged.
b.
Clean needle valve orifice of spray tip (Figure 4, Item 5) with carbon remover (Figure 4, Item 26).
c.
Clean spray tip (Figure 4, Item 5) orifices with pin vise (Figure 4, Item 28) and cleaning wire
(Figure 4, Item 27).
CAUTION
Do not buff spray tip area excessively. Do not use a steel rotary wire brush or spray tip
holes may be distorted.
d.
Clean exterior of spray tip with brass wire brush.
5
5
26
28
27
MAINT_278
Figure 4.
Injector Spray Tip Cleaning.
TM 9-2815-205-24
0084
0084-4


Back to Top