CLEANING - Continued
4.
Injector plunger and bushing:
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes; and do not breathe vapors. Keep away from heat or flame. Never
smoke when using cleaning solvent. Failure to comply may result in injury,
illness, or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa).
Use only with protective equipment (goggles, face shield, gloves, etc.). Failure
to comply may result in injury to personnel.
CAUTION
Ensure high pressure bleed hole in side of bushing is not plugged. If hole is plugged,
fuel oil will leak into engine and cause oil dilution.
NOTE
Keep plunger and bushing together as a matched set. Keep parts of each injector
assembly together.
Wash plunger and bushing with cleaning solvent and dry with compressed air.
END OF TASK
TM 9-2815-205-24
0084
0084-6