TM-9-2815-205-34

ENGINE WITH CONTAINER; MODELS 5063-5299, 5063-5392, 5063-5393, 5063-5395, 5063-5398, 5063-539F, 5063-539L

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

AUGUST 1992

  TM-9-2815-205-34 - Page 118 of 596

TM 9-2815-205-34
b. Cleaning/Inspection
(1)
(2)
(3)
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use In a well-ventilated area. Avoid contact with skin, e es, and
clothes. Do not breathe vapors. Do not use near open flame or excessive heat.
The flash point Is 100-138 Degrees F (38-50 Degrees C). If you become dizzy
while using cleaning solvent, get fresh air immediately and seek medical aid. If
contact with eyes Is made, wash with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI. Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.)
Clean drain receptacle, bracket, and filter element with dry cleaning solvent and dry with com-
pressed air.
Remove obstructions in hose using compressed air.
Check drain receptacle, retainer, and bracket for cracks or broken parts.
c. Assembly
(1) If removed, install two loop clamps (8) and hose clamp (10) on hose (11).
(2) Install machine screw (7), lower loop clamp (8), and nut (9) on bracket (6).
(3) Install drain receptacle (5), filter element (4), retainer (3), two flat washers (2), and two wing
nuts (1) on bracket (6).
END OF TASK
2-91


Back to Top