3-15. THERMOSTAT HOUSING AND CROSSOVER TUBE REPLACEMENT (MODELS 5063-5393
AND 5063-539L)
(Cont)
c. Installation
(1) Using thermostat seal installer and seal installer handle, press seal (29) in thermostat water
outlet (21). Position seal so lip will face away from thermostat.
(2) Install thermostat (27) in thermostat water outlet (21). If removed, install plug (29) in outlet.
NOTE
The transmission oil cooler as-
sembly (20) and thermostat
water outlet (21) were removed
in Para 2-4 to allow mounting
engine on maintenance stand.
(3) Install gasket (26), thermostat water outlet
(21), four lockwashers (24), four flat
washers (25), two short bolts (22), and two
long bolts (23) on top of transmission oil
cooler assembly (20). Torque bolts to
13-17 lb-ft (18-23 NŽm).