TM 9-2815-205-34
(10)
(11)
(12)
NOT E
If necessary, pry
rods apart before
side clearance.
connecting
measuring
Using thickness gage set, measure side
clearance between each pair of
connecting rods. Clearance must be
0.008 to 0.016 inch.
Repeat steps (1) thru (10) to install
additional liners, pistons, and rod
assemblies. Use hold-down clamps (1) to
hold each liner in place.
Remove all liner hold-down clamps (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Para Description
3-43 Install cylinder head.
3-35 Install oil pump inlet tubes.
3-33 Install oil pan.
3-213