TM 9-2815-210-34-2-2
4-24. CRANKCASE BREATHER TUBE ADAPTER.
a. Cleaning
There are no special cleaning procedures needed. Refer to
cleaning procedures given in para 4-3.
b .
Inspection and Repair.
FRAME 1
1.
Check that crankcase breather tube adapter (1) is not cracked, bent,
dented or damaged in any other way.
If crankcase breather tube adapter is
damaged in any way, get a new part.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when sol-
vent is used.
Use only in well-ventilated places. Failure
to do this may result in injury to personnel and damage
to equipment.
2.
Check that crankcase breather tube adapter (1) has no minor nicks,
scratches or burrs.
To take out minor nicks, scratches or burrs, use
a fine mill file or crocus cloth dipped in dry cleaning solvent.
END OF TASK
4-278