TM-9-2815-210-34-2-2

ENGINE ASSEMBLY, DIESEL (MULTIFUEL): NATURALLY ASPIRATED OR TURBOCHARGED, FUEL-INJECTED, WATER-COOLED, 6-CYLINDER

TECHNICAL MANUAL; TROUBLESHOOTING; DIRECT SUPPORT AND GENERAL SUPPORT LEVEL; VOLUME 2 OF 2; PART 2 OF 2

APRIL 1981

  TM-9-2815-210-34-2-2 - Page 304 of 968

TM 9-2815-210-34-2-2
c .
Inspection and Repair.
FRAME 1
1.
Check that breather valve housing (1), breather valve spring housing (2),
breather valve end cover (3), and breather tube adapter (4) have no cracks.
If any of these parts is cracked, throw away crankcase breather valve
assembly and get a new one.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame.
Keep a fire extinguisher nearby when sol-
vent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
2.
Check that breather valve housing (1), breather valve spring housing (2),
breather valve end cover (3), and breather tube adapter (4) have no nicks,
burrs or raised metal.
Fix minor nicks, burrs, and raised metal with a fine
mill file or a crocus cloth dipped in dry cleaning solvent.
3.
Check that four nuts (5) and all screws (6) have no thread damage. Throw
away damaged nuts and screws and get new ones.
4.
Check all threaded holes in breather valve housing (1). Fix minor thread
damage with a tap.
GO TO FRAME 2
4-285


Back to Top