TM 9-2815-210-34-2-2
4-40. FUEL INJECTOR NOZZLE AND HOLDER ASSEMBLIES.
NOTE
This task is shown for one fuel injector nozzle
and holder assembly.
This task should be done
for all fuel injector nozzle and holder assemblies.
a.
Tests and Checks.
(1) Nozzle
WARNING
The high fuel pressure used during these tests and
checks can puncture the skin and cause blood
poisoning and possible death. Keep hands away
from nozzle.
opening pressure test.
FRAME 1
1.
2.
3.
WARNING
Carbon removing solvent is flammable. Do not use near
an open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
CAUTION
Make sure no dirt gets in nozzle and holder assembly (1).
Dirt can damage equipment.
Using carbon removing solvent, clean nozzle area (2).
Screw connector tube (3) into nozzle and holder assembly (1).
Fill reservoir (4) with fuel.
Close pressure valve gate (5). Pump handle (6)
about 25 times or until air is cleared from nozzle an-d holder assembly (1).
GO TO FRAME 2
4-394