MWO 5--2350--262--35--4
5--5
SECTION II INSTALLATION AND PRELIMINARY ROUTING OF HDC CABLE
ASSEMBLIES -- CONTINUED
NOTE
Steps e through p apply to Figure 5--3.
e.
Position nutplate, M85049/95--22A, (2) over upper cable assembly W2J1 end of cable (3) at center
location on back of umbilical cable disconnect bracket (7). Place dustcap lanyard (4) behind top left
screw on connector (6) between connector and bracket. Refer to Figure 5--3 for illustration of typical
connector installed on umbilical cable disconnect bracket (7).
f.
Attach upper cable assembly connector W2J1 (3) and dustcap lanyard (4) to nutplate (2) using four
screws, MS24667--4, (1).
g.
Place dustcap, D38999/33W23R, (5) over exposed cable connector W2J1.
h.
Ensure upper cable assembly W2 (8) is not bent or twisted during installation on umbilical cable
disconnect bracket (7).
Figure 5--3. Typical Cable Connector Installation