MWO 5--2350--262--35--4
5--10
SECTION II INSTALLATION AND PRELIMINARY ROUTING OF HDC CABLE
ASSEMBLIES -- CONTINUED
NOTE
Steps v and w below apply to Figure 5--6. Reference should also be made to FO 5--3.
v.
From inside driver’s compartment, uncoil single connector end J1 (3) of power cable assembly W1,
12496953, (1) and place as shown in Figure 5--6.
w.
Carefully place cable connector W1J1 near back of umbilical cable disconnect bracket, 12496964, (2).
NOTE
It may be necessary to file a small notch in left most opening in umbilical cable
disconnect bracket to allow the three “ears” on connector W1J1 to pass through opening
in bracket.
NOTE
Step x below applies to Figure 5--6.
x.
Orient large key (1) of cable connector W1J1 at 12 o’clock position and place in left most opening in
umbilical cable disconnect bracket (3) as shown for a typical connector.
FO 5--3. Power Cable Assembly W1
NOTE
Step y below applies to Figure 5--6.
y.
Uncoil remainder of power cable assembly W1 and route 1070 branch of cable to parking brake relay
area in front portion of driver’s compartment.
Figure 5--6. Initial Routing of Power Cable Assembly W1