MWO-5-2350-262-35-4

ARMORED COMBAT EARTHMOVER (ACE), M9

MODIFICATION WORK ORDER

  MWO-5-2350-262-35-4 - Page 147 of 207

MWO 5--2350--262--35--4
5--12
SECTION III ELECTRICAL CONNECTION OF HDC CIRCUIT BREAKER --
CONTINUED
NOTE
Wiring connections to parking brake relay should be made using screws attached to
relay. New lockwashers should be used. If attaching screws are damaged or missing,
obtain new screws locally.
NOTE
Step g below applies to Figure 5--8. Reference should also be made to FO 5--4.
g.
Connect lead assembly, 12496958, (labeled 1070) between right terminal of HDC circuit breaker on
umbilical cable disconnect bracket and terminal B2 (lower right terminal) on parking brake relay. New
lockwashers should be used on parking brake relay terminals. Refer to Figure 5--8.
Figure 5--8. Parking Brake Relay Terminals


Back to Top