MWO 5--2350--262--35--4
5--6
SECTION II INSTALLATION AND PRELIMINARY ROUTING OF HDC CABLE
ASSEMBLIES -- CONTINUED
i.
Position nutplate (2) over lower cable assembly W3J1 end of cable (3) at right most connector location on
back of umbilical cable disconnect bracket (7). Place dustcap lanyard (4) behind top left screw on
connector (6) between connector and bracket. Refer to Figure 5--3 for illustration of typical connector
installed on umbilical cable disconnect bracket (7).
j.
Attach lower cable assembly connector W3J1 (3) and dustcap lanyard (4) to nutplate (2) using four
screws (1).
k.
Place dustcap (5) over exposed cable connector W3J1.
l.
Ensure lower cable assembly W3 (8) is not bent or twisted during installation on umbilical cable
disconnect bracket (7).
m. Position nutplate, M85049/95--12A, (2) over power cable assembly W1J1 end of cable (3) at left most
connector location on back of umbilical cable disconnect bracket (7). Place dustcap lanyard,
MS3181--12CA, (4) behind top left screw on connector (6) between connector and bracket. Refer to
Figure 5--3 for illustration of typical connector installed on umbilical cable disconnect bracket (7).
n.
Attach power cable assembly connector W1J1 (3) and dustcap lanyard (4) to nutplate (2) using four
screws, MS24667--4, (1).
o.
Place dustcap (5) over exposed cable connector W1J1.
p.
Ensure power cable assembly W1 (8) is not bent or twisted during installation on umbilical cable
disconnect bracket (7).
Figure 5--3. Typical Cable Connector Installation