MWO 5--2350--262--35--4
5--14
SECTION IV ROUTING AND ELECTRICAL CONNECTION OF POWER
CABLE ASSEMBLY W1 -- CONTINUED
NOTE
Step c below applies to Figures 5--10 and 5--11.
c.
Route 1069 branch of cable W1 from disconnect bracket to the wall of the operator’s compartment just
above the NBC filter, as shown in Figures 5--10 and 5--11.
d.
Cut excess cable, install terminal lug, MS25035--154, and crimp onto end of cable W1.
e.
Remove bolt along with existing ground wires from compartment wall. Do not remove existing ground
wires from bolt.
f.
Install 1069 branch of cable W1 on end of bolt and reinstall bolt with wires to compartment wall as shown
in Figure 5--11.
g.
Secure 1069 branch of cable W1 wiring to vehicle as necessary using tiedown straps, MS3367--1--9, and
by routing cable through existing cable clamps. It is not necessary to remove cable clamps during cable
rounting process.
Figure 5--10. Routing Cable Assembly W1 Branch 1069 From Disconnect Bracket