TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 114 of 266

TM 9–1200–215–34&P
3–23
3–19.
DU CONTROL PANEL SWITCH BOOT MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits,TK–100/G (item 48, Appendix E)
Materials/Parts:
Sealing Compound (item 25, Appendix D)
Equipment Conditions:
Unenergized DU on workbench.
Personnel Required:
One MOS 35Y
a.
REMOVAL
NOTE
Ensure that switch(es) do not drop
to the inside of DU when removing
boot from control panel.
1.
Remove two screws (1) from switch guard (2).
2.
Lift switch guard (2) and unscrew switch boot
(3) from switch (4).
3.
Remove switch boot (3), switch guard (2), and
seal washer (5) that secure switch (4) to
control panel.
4.
Lift switch guard(s) (6) and unscrew switch
boots(s) (7) from switch(es) (8).
5.
Remove switch boot(s) (7), switch guard(s) (6),
and seal washer(s) (9) that secure switch(es)
(8) to control panel.
b.
INSTALLATION
1.
Install seal washer(s) (9), switch guard(s) (6),
and switch boot(s) (7) securing switch(es) (8)
to control panel.
2.
Install seal washer (5), switch guard (2), and
secure guard to control panel using two screws
(1).
3.
Install switch boot (3) on switch (4) securing
switch to control panel.
1
2
3
4
5
6
7
8
9
6
7
8
9


Back to Top