KEYBOARD CABLE ASSEMBLY MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
3/16” Flat Tip Screwdriver Socketwrench
(item 23, Appendix E)
Work Station Kit, Electronic (item 38, Appendix E)
Equipment Conditions:
DU bottom cover removed; if not, remove bottom
cover in accordance with paragraph 3–13
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The DU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground, to ensure ESD protection.
2.
Unscrew two captive screws (1) securing
connector A1P3 (2) to EL panel receptacle (3).
Disconnect connector.
3.
Unscrew two captive screws (4) securing
connector A2P1 (5) to switch panel receptacle
J1 (6). Disconnect connector, and remove
cable assembly from DU housing.
1
2
4
5
3
6