TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 104 of 266

TM 9–1200–215–34&P
3–13
3–15.
SWITCH PANEL MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
3/16” Flat Tip Screwdriver Socketwrench
(item 23, Appendix E)
Work Station Kit, Electronic (item 38, Appendix E)
#2 Crosstip Screwdriver Socketwrench
(item 22, Appendix E)
Materials/Parts:
Lockwasher (item 1, Appendix F)
Personnel Required:
One MOS 35Y
Equipment Conditions:
DU bottom cover removed; if not, remove bottom
cover in accordance with paragraph 3–13
a.
REMOVAL
CAUTION
ESD SENSITIVE
The DU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground, to ensure ESD protection.
2.
Unscrew two screws (1) securing connector
A2P1 (2) to switch panel receptacle A2J1 (3)
and disconnect connector from switch panel.
3.
Unscrew two screws (4) securing connector
A2P2 (5) to switch panel receptacle A2J2 (6)
and disconnect connector from switch panel.
4.
Remove screw (7), lockwasher (8), flat washer
(9), and cable clamp (10) securing DU–Serial
cable assembly to DU housing. Discard
lockwasher.
3
4
5
6
8
9
7
10
1
2


Back to Top