3–16.
HANDLE MAINTENANCE INSTRUCTIONS CONTINUED
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The DU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground, to ensure ESD protection.
2.
Install handle (3) with two new preformed
packings (4)
into housing so handle rotates
toward bottom of DU (toward housing
mounting feet). Ensure preformed packings (4)
seat evenly against housing.
3.
Install two washers (2) and two new
self–locking nuts (1) on handle. Torque nuts to
140
"
5 in.–lb (15.8
"
.6 N
S
m).
4.
Install DU bottom cover following procedure
outlined in paragraph 3–13.