TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 102 of 266

TM 9–1200–215–34&P
3–11
3–14.
ELECTROLUMINESCENT PANEL MAINTENANCE INSTRUCTIONS CONTINUED
a.
REMOVAL CONTINUED
6.
Remove eight hex head screws (14) and 12
flat washers (15) securing EL panel (16) to DU
housing. Remove EL panel from DU housing.
7.
Remove filter glass (17) from EL panel (16).
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged. Handle with care when
removing or replacing it. Failure to
comply may result in damage to
equipment.
8.
Remove EMI shielding gasket (18) from filter
glass (17).
9.
Inspect EMI shielding gasket (18) for cuts,
nicks, and signs of stretching. Discard EMI
shielding gasket if unserviceable.
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The DU contains ESD sensitive
components. Wear a protective
ESD wrist strap whenever handling
components. Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground, to ensure ESD protection.
CAUTION
The EMI shielding gasket is vital to
this piece of equipment and is easily
damaged. Handle with care when
removing or replacing it. Failure to
comply may result in damage to
equipment.
2.
Position EMI shielding gasket (18) on filter
glass (17).
18
17
15
14
16
15
14


Back to Top