TM 9–1200–215–34&P
4–10
4–14.
TOP COVER ASSEMBLY, NEOPRENE RUBBER STRIP(S) CONTINUED
b.
INSTALLATION
CAUTION
ESD SENSITIVE
•
The PDIU contains ESD sensitive
components.
Wear a protective
ESD wrist strap whenever handling
components.
Failure to comply may
result in damage to equipment.
•
Damage to RFI/EMI contact strip
may occur.
Do not slide cover off of
housing.
Pick cover straight up.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
2.
Cut strip(s) from neoprene rubber stock
3–15/16 inches long by 1 inch wide.
Return
any excess to supplies.
3.
Apply adhesive to neoprene rubber strip(s) (1).
4.
Press neoprene rubber strip(s) (1) in place on
cover (2) using mounting dimensions shown.
Allow to cure for 20 minutes.
5.
Install top cover (2) in accordance with
procedure outlined in paragraph 4–13.
2
2–5/16 IN.
1–3/8 IN.
1 IN.
1–3/8 IN.
2–5/16 IN.
3–15/16 IN.
1