TM 9–1200–215–34&P
4–13
4–16.
CIRCUIT CARD ASSEMBLIES (CCAs) A2, A3, A4, AND A5
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kit, JTK–17LAL (item 34, Appendix E)
Tool Kit, General Mechanic’s (item 42, Appendix E)
Torque Wrench, 0–75 in.–lb (item 40, Appendix E)
Bit, Screwdriver (item 44, Appendix E)
Work Station Kit, ESD (item 38, Appendix E)
Materials/Parts:
Sack, Shipping (item 23, Appendix D)
Equipment Condition:
Top cover assembly removed; if not, remove top
cover in accordance with paragraph 4–13
Personnel Required:
One MOS 35Y
a.
REMOVAL
CAUTION
ESD SENSITIVE
The PDIU contains ESD sensitive
components.
Wear a protective
ESD wrist strap whenever handling
components.
Failure to comply may
result in damage to equipment.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
NOTE
Note position of CCAs when
removing to aid in installation.
2.
Loosen two screws (1) on card holder (2) of
CCA to be removed.
3.
Remove CCA.
1
2
A2
A3
A4
A5


Back to Top