ELECTRICAL INDICATOR PANEL, LEDs DS1 AND DS2 CONTINUED
b.
INSTALLATION
CAUTION
ESD SENSITIVE
The PDIU contains ESD sensitive
components.
Wear a protective
ESD wrist strap whenever handling
components.
Failure to comply may
result in damage to equipment.
Damage to RFI/EMI contact strip
may occur.
Do not slide cover off of
housing.
Pick cover straight up.
1.
Attach ESD grounding strap to wrist and
ground to ensure ESD protection.
WARNING
Do not breathe fumes from
adhesive/sealant.
Use with
adequate ventilation.
Adhesive/sealant may cause eye or
skin irritation, avoid direct contact.
2.
Apply a thin coating of adhesive/sealant to the
panel mounting surface of DS1 (1) or DS2 (2).
3.
Insert DS1 (1) or DS2 (2) into panel (5) and
install lockwasher (4) and nut (3).
4.
Cut the leads of DS1 (1) or DS2 (2) back to
1/2–inch of the panel (5).
5.
Using flux and solder, solder leads to DS1 (1)
or DS2 (2).
Remove tags.
6.
Clean solder joints with acid swabbing brush
and alcohol.
7.
Install Electrical Indicator Panel in accordance
with procedure outlined in paragraph 4–18.